<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01717nam a22002297a 4500</leader>
  <controlfield tag="003">OSt</controlfield>
  <controlfield tag="005">20260604084116.0</controlfield>
  <controlfield tag="008">260604b        |||||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">9780444511010</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">DLC</subfield>
    <subfield code="b">En</subfield>
    <subfield code="c">DLC</subfield>
  </datafield>
  <datafield tag="050" ind1=" " ind2=" ">
    <subfield code="a">QD75.4.S24 S2535</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Sample preparation for trace element analysis /</subfield>
    <subfield code="c">edited by Z. Mester, R. Sturgeon.</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Boston:</subfield>
    <subfield code="b">Elsevier,</subfield>
    <subfield code="c">2003.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">lii, 1286 p. :</subfield>
    <subfield code="b">ill. ;</subfield>
    <subfield code="c">24 cm.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references and index</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Trace element analysis plays a critical role in environmental monitoring, food safety, clinical diagnostics, and industrial quality control. 
The accuracy and reliability of trace element determination depend significantly on effective sample preparation procedures. 
This study reviews common sample preparation techniques, including acid digestion, microwave-assisted digestion, dry ashing, solvent extraction, and solid-phase extraction. 
The advantages and limitations of each method are discussed with respect to sample type, analyte stability, contamination risks, and detection requirements. 
Recent advances in automated and green sample preparation technologies are also highlighted.
 Proper optimization of preparation protocols minimizes matrix interferences and enhances analytical sensitivity, ensuring accurate quantification of trace elements at ultra-trace levels.</subfield>
    <subfield code="u">http://172.20.27.22:4000/handle/123456789/174</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2=" ">
    <subfield code="2">CHEMISTRY</subfield>
    <subfield code="a">Sample preparation</subfield>
    <subfield code="b">Trace elements--Analysis</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">MESTER, Zolta'n</subfield>
    <subfield code="e">Editor</subfield>
    <subfield code="q">Zolta &#xB4;n Mester</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">STURGEON, Raph</subfield>
    <subfield code="e">Editor</subfield>
    <subfield code="q"> Ralph Sturgeon</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">http://172.20.27.22:4000/handle/123456789/174</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">lcc</subfield>
    <subfield code="c">BK</subfield>
    <subfield code="n">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">4449</subfield>
    <subfield code="d">4449</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">lcc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">SCI</subfield>
    <subfield code="a">DL</subfield>
    <subfield code="b">DL</subfield>
    <subfield code="d">2026-06-04</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">DUCE QD75.4.S24 S2535</subfield>
    <subfield code="r">2026-06-04 08:44:01</subfield>
    <subfield code="u">http://172.20.27.22:4000/handle/123456789/174</subfield>
    <subfield code="w">2026-06-04</subfield>
    <subfield code="y">BK</subfield>
  </datafield>
</record>
